How to Eliminate HPLC Ghost Peaks? Aijiren Torque-Deformation-Contamination Control Technology Case Study
Knowledge
categories
INQUERY

Comprehensive Solution for HPLC Dynamic Contamination: From Torque Failure to 3-Layer Composite Sealing

Apr. 24th, 2025
 

​I. Root Cause Analysis: The Hidden Culprit of Dynamic Contamination​​


A European pharmaceutical company's anticancer drug production line encountered HPLC detection anomalies, with persistent unknown interference peaks following the main peak. Laboratory investigations traced the contamination source to chromatographic vial sealing systems. Aijiren's technical team identified the root causes through the following findings:

​​Dynamic Contamination Signatures​​
Ghost peaks exhibited retention time drift (±0.3-1.5 min), indicating cyclic adsorption-desorption between contaminants and the mobile phase.

​​Material Correlation​​
LC-MS coupled detection revealed PTFE characteristic fragments (C8F16, m/z 412.96) in unknown peaks, chemically matching chromatographic vial septums (99.2% alignment).

​​Core Mechanism​​
Abnormal sealing torque caused microstructural damage to septums, generating 50-200μm particles that entered chromatographic columns via mobile phase flow.


​​
II. Experimental Validation: Breakthrough in Torque-Deformation-Contamination Correlation​​


Aijiren established a complete evidence chain through torque-HPLC coupled testing:

​​Torque Gradient Simulation​​
Three-tier torque settings (low/medium/high) covering production line ranges revealed a "brittle fracture → flexible deformation" transition zone via high-speed microscopy.
SEM confirmed: Over-torque (>2.5Nm) induced stress concentration, while under-torque (<1.0Nm) accelerated vibration-induced particle shedding.

​​Contamination Dynamics Tracking​​
Laser particle analyzer monitored real-time particulate concentrations in mobile phase across torque-calibrated samples.
Developed a 3D model linking torque values, particle release volume, and ghost peak area for production line optimization.





​​
III. Aijiren Solutions: Integration of Technological Depth & Industrial Implementation​​


As a global leader in laboratory consumables, Aijiren builds comprehensive prevention chains through material innovation, intelligent manufacturing, and service systems:

​​Material & Process Innovations​​

​​Composite Septum Technology​​: PTFE corrosion-resistant layer integrated with buffer structure, achieving 300% deformation resistance (-80℃ to 150℃ compatibility).
​​Intelligent Torque Control​​: Vial diameter-adaptive algorithms with temperature compensation modules (±0.05Nm precision).

​​Full-Scenario Product Matrix​​

​​Chromatography Consumables​​: Auto-sampler vials, multi-type sealing systems, gradient filtration modules (UHPLC/HPLC compatibility).
​​Water Analysis Tools​​: COD test tubes with ppb-level precision for trace contaminants.

​​Agile Global Service Network​​

48-hour global delivery via 6 automated lines (500k units/day, Class 100K cleanrooms)
Custom solutions: Micro-inserts, HF-resistant seals, dynamic contamination simulators.
        hplc vial headspace vial
 
 


​​IV. Client Value: From Problem-Solving to Risk Prevention​​


​​Why Aijiren?​​


​​Cost Efficiency​​: 30% cost reduction through scaled intelligent manufacturing and lean management.
​​Risk Mitigation​​: Zero-defect delivery with blockchain-enabled traceability (FDA 21 CFR Part 11 compliance).
​​Technical Leadership​​: Torque-HPLC coupled solutions address dynamic contamination and column efficiency decay industry-wide.