Non-sterile Disposable Syringe Filter
Product
    • non-sterile syringe filters
    • dispsable syringe filter
    • syringe filters wholesale
    • syringe filters supplier in China
    • syringe filters for sale
    non-sterile syringe filters

    Non-sterile Disposable Syringe Filter

    1.Membrane: PTFE, PVDF, PES, MCE, NYLON, PP, CA, etc.
    2.Pore Size: 0.22um / 0.45um
    3.Diameter: 13mm / 25mm
    4.House Material: PP
    5.Process Volume(ml): 13mm<10ml; 25mm<100ml
    product description

    Descriptions

    In HPLC analysis, the particle size of the chromatographic column packing is small and it is easy to be blocked by impurity particles. Therefore, samples and solvents need to be filtered in advance to remove particulate contaminants and protect the instrument.

    Ion chromatography, which is commonly used in environmental analysis, also requires that no inorganic pollutants be introduced in sample pretreatment.

    Syringe filters can be used in HPLC analysis and IC analysis to filter sample solutions, which is an important step in the sample pretreatment process.

    Membrane Characteristics

    Membrane Material

    Characteristic

    PTFE

    hydrophilic or hydrophobic, resistant to strong acid, strong alkali and high temperature, suitable for the filtration of strong corrosive solution, organic solution and gas.

    PVDF

    hydrophilic or hydrophobic, low protein binding, suitable for general biological filtration, not suitable for filtration of highly corrosive liquids.

    Nylon

    hydrophilic, high protein binding, suitable for protein-free aqueous and organic solutions, resistant to alcohol and DMSO.

    PES

    hydrophilic, low protein binding, high flow rate, high porosity, not resistant to organic

    CA

    hydrophilic, low protein binding, suitable for the filtration of proteins and aqueous solutions in biological samples, such as serum culture medium filtration.

    MCE

    Excellent contrast for easier particle detection, high degree of internal surface area, Higher dirt loading capacity, high flow rates, Thermally stable



    The following chart will help you quickly choose the proper filter membrane type.

    Features of Your Applictaions:

    Compatible Filter Membrane Type:

    Hydrophilic Syringe Filter

    PES, Nylon, MCE, Hydrophilic PTFE or PVDF

    Hydrophobic Syringe Filter

    Hydrophobic PTFE

    Compatible with aqueous samples only

    CA, Nylon, or PES

    Compatible with organic and aqueous samples

    Hydrophilic PTFE, Nylon, or Hydrophilic PVDF

    Compatible with gaseous samples

    MCE, or PTFE

    Can handle high temperature liquids <100 ℃

    PES, MCE, or PTFE

    Low protein binding

    MCE, PES, , Hydrophilic PVDF or Hydrophilic PTFE

    Nonspecific binding

    Nylon or PVDF

    Excellent flow rates

    MCE, Nylon, PES, PTFE, or PVDF

    High throughput loading

    Nylon, or PTFE

    Autoclave by 125℃for 15 minutes

    Nylon, MCE, PES, PTFE or PVDF


    Syringe Filter Diameter:

    13 mm Syringe Filters

    For sample volumes <10 mL range;

    Holdup (dead) volume is <30 ul.

    Maximum operation pressure <100psi

    Filter area: 0.85cm2

    25 mm Syringe Filters

    For sample volumes <100 mL range;

    Holdup (dead) volume is <100 ul.

    Maximum operation pressure <89 psi

    Filter area: 4.3cm2

    Syringe Filter Membrane Pore Size:

    0.22um: Sterilization grade filter membrane, sometimes written as 0.2um, can remove very fine particles in samples and mobile phases; it can meet the requirements of 99.99% sterilization specified by GMP or Pharmacopoeia;

    0.45μm: usually used for pretreatment to reduce the microbial load and filter out most bacteria and microorganisms; conventional sample and mobile phase filtration can meet general chromatographic requirements;

    1-5μm: To filter larger particles of impurities, or for the pretreatment of difficult-to-handle turbid solutions, it can be filtered with a 1-5μm membrane first, and then filtered with the corresponding membrane.

    Applications:

    • HPLC aqueous sample preparation

    • Biological sample preparation

    • Buffer solutions

    • Salt solutions

    • Tissue culture media

    • Irrigation solutions

    • Sterile isolation

    • Medical use, sterile filtering protein solution, tissue culture media, additives.

    Related Service

    1) OEM Manufacturing welcome: Customized Logo, Customized Package

    2) Professional After-sales Service Team

    3) Fast delivery, all goods can be shipped in 3-7days. Large qty products are in stock for customer.

    4) Shipping way: Based on customer’s difference situation using difference shipping ways, By air, By sea, By train,etc.

    5) Packing: Individually packaged, 100pcs per pack, 40PK/carton.56*50*26cm.12.5KG.packed in PP-Trays with plastic film and cover plate,neutral cartons outside OEM packing can be also provided.


    Company Introduction

    Founded in 2007, Zhejiang Aijiren, Inc. covers more than 10000 square meters, and has clean workshop more than 2000 square meters. 100, 000 class cleaning room;  

    15 years export experience, exprot to more than 70 countries, 2000+ customs around the world; 

    IS0, GMP & Bureau Veritas certificated, this is how we keep good quality and competitive prices for global valued customers.

    FAQ
    Inquiry
    Related products
    Inquiry